TL101 installation

Install the device under the equipment cover or in the battery compartment. Avoid locations shielded by metal.

  1. Connect the black harness wire to the negative battery terminal and the red wire to the positive terminal.
  2. Pass the cable leading to the battery through the current sensor opening, with the arrow on the sensor pointing toward the battery.
  3. Place the temperature sensor near the component to be monitored.
  4. Connect the digital inputs and outputs if needed. Check that the ring terminals are secure and insert the harness connector into the device until it is secured.
  5. Secure the device with cable ties or double-sided tape.

Data access​

To access data, scan the QR code on the information label and enter the device serial number (S/N) on the resulting site.