Skip to main content

IND1X CAN protocol

Communication settings​

  • CAN 2.0B, standard 11-bit identifiers; ISO 11898 physical layer.
  • Default speed: 250 kbit/s. Message types and identifiers are CANopen-compatible.
  • Multibyte values use little-endian byte order; signed values use two's complement.
  • The base IND1X Node ID is 0x68. The table lists identifiers for this Node ID.

Messages​

IDMessageDirectionLengthInterval
0x1E8Status 1 (TPDO1)IND1X → all8 bytes100 ms
0x4E8Identification (TPDO4)IND1X → all8 bytes1000 ms

Status 1 — 0x1E8​

BytesTypeContents
0i8Ambient temperature, 1 °C/bit; 0x80 (−128) means unavailable
1–7—Reserved

The value 0x80 is transmitted when measurement fails or the temperature sensor is not installed.

Identification — 0x4E8​

BytesTypeContents
0–3u32Device UID
4u8Hardware revision
5u8Firmware major version
6u8Firmware minor version
7u8Firmware patch version