BMS201 block diagram
The diagrams show two BMS201 power connection options: a common terminal for the charger and load, or separate charge and discharge terminals. In both options, switching takes place in the positive power path, and the battery, charger and load negative terminals are connected together outside the board.
Common charge and discharge terminal
In this option, the charger and load positive terminals connect to the common L+ terminal, and their negative terminals connect to B−. The shared external block in the diagram is labelled Load / Charger.
The current-sense shunt and the Charge and Discharge MOSFET switches are connected in series between B+ and L+. The Precharge branch consists of a switch and a resistor connected in parallel with the Discharge switch. It limits inrush current while charging the load's input capacitors before the discharge switch is turned on.
Separate charge and discharge terminals
The charger connects between C+ and B−, while the load connects between L+ and B−. The C+ terminal connects to the junction between the Charge and Discharge switches, and L+ is located after the discharge switch. The charger path therefore bypasses the Discharge switch, while the power path from B+ to the load passes through both main switches. As in the first option, the Precharge branch is connected in parallel with the Discharge switch.
C+ terminalConnecting a load to C+ can allow the battery to discharge regardless of the switch state. Do not use C+ to connect a load.
Labels and functional blocks
| Label or block | Function |
|---|---|
B+, B− | Battery positive and negative terminals. |
C+ | Charger positive terminal in the separate connection option. |
L+ | Common positive terminal for the charger and load in the first diagram; load positive terminal in the second. |
| Cells | Series-connected battery cells. |
| Fuse | Fuse in the battery positive circuit, before the current sensor. |
| Current Sense | Battery current measurement using the voltage drop across the integrated current-sense resistor (shunt). |
| Charge, Discharge | MOSFET switches that control charging and discharging in the positive power path. |
| Precharge | Switch and resistor that limit inrush current while charging the load's input capacitors. |
| Voltage Monitor & Balancing | Measurement of each series-connected cell's voltage and passive cell balancing. |
| NTC | External negative temperature coefficient thermistors for battery temperature monitoring. |
| Microcontroller Unit | Measurement processing and control of the power switches, balancing and external interfaces. |
| Digital Inputs & Outputs | Two inputs and two outputs for external circuits. The outputs are galvanically isolated dry contacts; the inputs are referenced to signal GND and are not galvanically isolated. |
| Wireless Interfaces (optional) | Optional interfaces for wireless communication and configuration, available with the corresponding module installed. |
| Relay | Dedicated electronic switch controlling the heater or cooler output. |
| Heater / Cooler | External device for battery temperature control, connected between the switched output and the common battery negative connection. |
| Battery State of Charge Indicator | External indicator of the battery's state of charge. |
| Charger | External device for charging the battery. |
| Load | External device that draws power from the battery. |
For signal connector pin assignments and power terminal functions, see Connectors.