BMS201 connectors
The diagrams show the board connector viewed from the cable connection side. Diagrams are simplified and not to scale.
Connector locations
Connector overview
| Designator | Function | Board connection |
|---|---|---|
| XP1 | Two digital inputs and two outputs | KLS PH, 2 mm pitch |
| XP3, XP5 | CAN1, CAN2 and peripheral power | KLS PH, 2 mm pitch |
| XP4 | Cell voltage measurement and balancing | KLS PH, 2 mm pitch |
| XP8 | Configuration USB | KLS PH, 2 mm pitch |
| XP10 | Three external temperature sensors | KLS PH, 2 mm pitch |
| XP11 | Pushbutton | KLS PH, 2 mm pitch |
| B+, C+, L+ | Battery, charger and load | M6 threaded terminals |
| XP15 | Heater / cooler | M4 threaded terminal |
| XP12, XP13 | NET10 communication module | Internal connection |
XP1 — digital inputs and outputs
| Parameter | Specification |
|---|---|
| Board header | KLS L-KLS1-XL1-2.00-08-R, right-angle, 2 mm pitch |
| Mating housing | L-KLS1-XL1-2.00-08-H |
| Female crimp contacts | L-KLS1-XL1-2.00-T, 8 pcs. |
| Wire | AWG 30–24 (≈ 0.05–0.2 mm²) |
| JST PH alternative | PHR-8 housing, SPH-002T-P0.5S contacts |
| Pin | Signal | Direction | Description and electrical characteristics |
|---|---|---|---|
| 1 | IN1+ | Input | DI1, 10 kΩ pull-up to internal 3.3 V |
| 2 | IN1− | Input return | DI1 return through 120 Ω to GND |
| 3 | IN2+ | Input | DI2, 10 kΩ pull-up to internal 3.3 V |
| 4 | IN2− | Input return | DI2 return through 120 Ω to GND |
| 5 | OUT1A | Output | First terminal of normally open solid-state relay DO1 |
| 6 | OUT1B | Output | Second DO1 terminal, with a 120 Ω series resistor |
| 7 | OUT2A | Output | First terminal of normally open solid-state relay DO2 |
| 8 | OUT2B | Output | Second DO2 terminal, with a 120 Ω series resistor |
The inputs share GND and are not galvanically isolated. Do not apply an external voltage to the inputs.
DO1 and DO2 are galvanically isolated. They do not supply voltage (dry contacts).
XP3 and XP5 — CAN1 and CAN2
For each connector:
| Parameter | Specification |
|---|---|
| Board header | KLS L-KLS1-XL1-2.00-04-R, right-angle, 2 mm pitch |
| Mating housing | L-KLS1-XL1-2.00-04-H |
| Female crimp contacts | L-KLS1-XL1-2.00-T, 4 pcs. |
| Wire | AWG 30–24 (≈ 0.05–0.2 mm²) |
| JST PH alternative | PHR-4 housing, SPH-002T-P0.5S contacts |
| Pin | Signal | Direction | Description and electrical characteristics |
|---|---|---|---|
| 1 | 3V3_EXT | Power output | Nominal 3.3 V relative to pin 4; no more than 500 mA |
| 2 | CANH | Bidirectional | CAN High of the corresponding channel |
| 3 | CANL | Bidirectional | CAN Low of the corresponding channel |
| 4 | GND | Common | Signal ground, connected to battery negative |
Each channel uses a 3.3 V transceiver and electrostatic discharge protection. There is no galvanic isolation. CANH and CANL form a differential bus.
A 120 Ω termination resistor on each channel is permanently connected between CANH and CANL.
XP4 — battery cells
| Parameter | Specification |
|---|---|
| Board header | KLS L-KLS1-XL1-2.00-13-R, right-angle, 2 mm pitch |
| Mating housing | L-KLS1-XL1-2.00-13-H |
| Female crimp contacts | L-KLS1-XL1-2.00-T, 13 pcs. |
| Wire | AWG 30–24 (≈ 0.05–0.2 mm²) |
| JST PH alternative | PHR-13 housing, SPH-002T-P0.5S contacts |
| Pin | Signal | Connection |
|---|---|---|
| 1 | CELL12, BAT+ | Cell 12 positive, top of the 12S stack and BMS supply |
| 2 | CELL11 | Cell 11 positive |
| 3 | CELL10 | Cell 10 positive |
| 4 | CELL9 | Cell 9 positive |
| 5 | CELL8 | Cell 8 positive |
| 6 | CELL7 | Cell 7 positive |
| 7 | CELL6 | Cell 6 positive |
| 8 | CELL5 | Cell 5 positive |
| 9 | CELL4 | Cell 4 positive |
| 10 | CELL3 | Cell 3 positive |
| 11 | CELL2 | Cell 2 positive |
| 12 | CELL1 | Cell 1 positive |
| 13 | GND, BAT− | Cell 1 negative, battery negative |
Cell numbering starts at battery negative.
The measurement range per cell is 0–5 V, and the input power voltage range is 16–70 V. The 70 V limit does not allow a cell to exceed 5 V. In 12S, the total at 5 V per cell is 60 V. These wires also serve balancing circuits and board power. Do not route load current through XP4.
For a 6–11S battery, connect all remaining cell measurement wires to the positive terminal of the last cell (battery positive). For example, for 6S, connect CELL6–CELL12 to the positive terminal of the sixth cell.
XP8 — USB
| Parameter | Specification |
|---|---|
| Board header | KLS L-KLS1-XL1-2.00-05-R, right-angle, 2 mm pitch |
| Mating housing | L-KLS1-XL1-2.00-05-H |
| Female crimp contacts | L-KLS1-XL1-2.00-T, up to 4 pcs.; position 5 unused |
| Wire | AWG 30–24 (≈ 0.05–0.2 mm²) |
| JST PH alternative | PHR-5 housing, SPH-002T-P0.5S contacts |
| Pin | Signal | Direction | Description and electrical characteristics |
|---|---|---|---|
| 1 | VUSB | From USB host | Nominal 5 V VBUS; connected only to a 0.1 µF capacitor |
| 2 | DN / USB_N | Bidirectional | USB D− |
| 3 | DP / USB_P | Bidirectional | USB D+ |
| 4 | UGND | USB return | Connected to GND through a ferrite filter |
| 5 | NC | — | Unconnected; leave unused |
VUSB does not power the internal BMS rails. A 5 V USB connection therefore does not establish battery-free operation. This connector provides no USB peripheral power output. Route D+ and D− as a twisted pair; pin 4 is the USB return, not an additional signal pin. USB is not galvanically isolated.
XP10 — temperature sensors
| Parameter | Specification |
|---|---|
| Board header | KLS L-KLS1-XL1-2.00-06-R, right-angle, 2 mm pitch |
| Mating housing | L-KLS1-XL1-2.00-06-H |
| Female crimp contacts | L-KLS1-XL1-2.00-T, 6 pcs. |
| Wire | AWG 30–24 (≈ 0.05–0.2 mm²) |
| JST PH alternative | PHR-6 housing, SPH-002T-P0.5S contacts |
| Pin | Signal | Description |
|---|---|---|
| 1 | TEMP1 | First temperature sensor input |
| 2 | GND | First sensor return |
| 3 | TEMP2 | Second temperature sensor input |
| 4 | GND | Second sensor return |
| 5 | TEMP3 | Third temperature sensor input |
| 6 | GND | Third sensor return |
Connect each external resistive sensor between TEMPn and its adjacent GND. These pins are not power outputs or battery-voltage inputs.
The B57164K0103J000 thermistor is used as the external temperature sensor.
XP11 — pushbutton
| Parameter | Specification |
|---|---|
| Board header | KLS L-KLS1-XL1-2.00-02-R, right-angle, 2 mm pitch |
| Mating housing | L-KLS1-XL1-2.00-02-H |
| Female crimp contacts | L-KLS1-XL1-2.00-T, 2 pcs. |
| Wire | AWG 30–24 (≈ 0.05–0.2 mm²) |
| JST PH alternative | PHR-2 housing, SPH-002T-P0.5S contacts |
| Pin | Signal | Description and electrical characteristics |
|---|---|---|
| 1 | BTN | Button input; 10 kΩ pull-up to 3.3 V, then a 1 kΩ resistor, a 0.1 µF capacitor and electrostatic discharge protection |
| 2 | Button return | Connected to GND through a 120 Ω resistor |
Connect a normally open dry contact across pins 1–2. The input is active when the contact is closed.
B+, C+ and L+ — power terminals
| Terminal | Function | Cable connection |
|---|---|---|
B+ | Battery positive, input to the built-in current sensor | M6 ring lug |
C+ | Charger positive | M6 ring lug |
L+ | Load positive | M6 ring lug |
Each terminal has one electrical contact.
| Parameter | Value |
|---|---|
| External thread | M6 |
| Maximum tightening torque | 3.9 N m |
Do not exceed the specified maximum tightening torque.
Fit an M6 ring lug over the threaded stud and secure it with an M6 nut. There is no mating housing or socket contact. Select the lug part number for the cable cross-section.
Switching takes place in the positive circuit. Battery, charger and load negative connections share an external return. Do not use signal connector GND pins as the power return.
The internal contactors are rated for 70 V, 100 A continuous, and 500 A for 1 s. These are product power-path ratings subject to cooling conditions, not signal connector ratings. The current sensor's ±250 A range is a measurement range, not the continuous board current rating. Cable, lug and temperature constraints also apply.
XP15 — heater / cooler output
| Pin | Signal | Description |
|---|---|---|
| 1 | POUT0 | Switched positive connection for an external heater / cooler |
| Parameter | Value |
|---|---|
| External thread | M4 |
| Maximum tightening torque | 1.2 N m |
Do not exceed the specified maximum tightening torque.
Use an M4 ring lug secured with an M4 nut. Select the lug part number for the cable cross-section.
A power MOSFET switches F+ to POUT0 with optically isolated gate control. F+ is the positive bus after the current sensor and before the power switches. Connect the load between XP15 and battery negative. When on, output voltage is close to battery voltage; there is no dedicated regulated heater supply.
XP12 and XP13 — NET10
Connectors XP12 and XP13 are intended for connecting the NET10 communication module.
When installing NET10, use the key and the mounting hole position to determine the correct orientation. The module can be inserted incorrectly, so check its orientation before mating the connectors.